SCOTSMAN INDUSTRIES INC -- NICKEL SAFE ICE MACHINE CLEANER -- 7930-00N078292
=====================  Product Identification  =====================

Product ID:NICKEL SAFE ICE MACHINE CLEANER
MSDS Date:01/19/1995
FSC:7930
NIIN:00N078292
=== Responsible Party ===
Company Name:SCOTSMAN INDUSTRIES INC
Address:HIGH 321 SOUTH
City:FAIRFAX
State:SC
ZIP:29827
Country:US
Info Phone Num:708-215-4539
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:SCOTS
=== Contractor Identification ===
Company Name:SCOTSMAN INDUSTRIES INC
Box:UNKNOW
CAGE:SCTSM
Company Name:SCOTSMAN INDUSTRIES, INC.
Address:HIGH 321 SOUTH
Box:City:FAIRFAX
Phone:708-215-4539
CAGE:SCOTS

=============  Composition/Information on Ingredients  =============

Ingred Name:PHOSPHORIC ACID (SARA 313) (CERCLA)
CAS:7664-38-2
RTECS #:TB6300000
Fraction by Wt: 50-65%
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3/3 STEL
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:CITRIC ACID
CAS:77-92-9
RTECS #:GE7350000
Fraction by Wt: <10%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SURFACTANT
CAS:68610-39-9
Fraction by Wt: <5%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: 20-40%
OSHA PEL:N/K 
ACGIH TLV:N/K 

Ingred Name:SUPDAT:DMG TO MOUTH & THROAT. IF INDIVIDUAL IS CONSCIOUS &
    ALERT, IMMED RINSE MOUTH W/WATER & DILUTE SWALLOWED (ING 6)
RTECS #:9999999ZZ

Ingred Name:ING 5:MATL W/MILK OR WATER. SEEK IMMED MEDICAL ATTENTION.
RTECS #:9999999ZZ

Ingred Name:SPILL PROC:CLEAN-UP PROCEDURES. PVNT MATL FROM ENTERING
    DRAINS, SEWERS, STREAMS/OTHER BODIES OF WATER. PVNT (ING 8)
RTECS #:9999999ZZ

Ingred Name:ING 7:FROM SPREADING. IF RUN-OFF OCCURS NOTIFY APPROP AUTH
    AS REQD. PUMP/VACUUM TRANSFER SPILLED PROD TO CLEAN (ING 9)
RTECS #:9999999ZZ

Ingred Name:ING 8:CNTNRS FOR RECOVERY. ABSORB UNRECOVERABLE PROD ON
    ABSORB MATLS. TRANSFER CONTAMD ABSORB & OTHER MATLS TO (ING 10)
RTECS #:9999999ZZ

Ingred Name:ING 9:CNTNR FOR NEUTRALIZATION. NEUT SPILLED MATL. FOLLOW
    LOCL, STATE, AND FED REGS FOR PROPER DISPOSAL.
RTECS #:9999999ZZ

Ingred Name:RESP PROT:SFTY EQUIP SUPPLIER. ENGINEERING AND/OR
    ADMINISTRATIVE CONTROLS SHOULD BE IMPLEMENTED TO REDUCE EXPOSURE.
RTECS #:9999999ZZ

Ingred Name:PROT GLOVES:NEOPRENE OR RUBBER.
RTECS #:9999999ZZ

Ingred Name:EYE PROT:& FULL LENGTH FACESHIELD 
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYES:EXPOS TO LIQUID, VAP/MIST
    MAY CAUSE SEVERE IRRIT. SYMPS MAY INCL STINGING, TEARING, REDNESS,
    SWELL, & EYE DMG. BURNING MAY NOT BE IMMED PAINFUL/VISIBLE.
    PRLNGD/RPTD EXPOS MAY CAUSE IRREVERS IBLE EYE DMG INCL CORNEAL DMG
    & BLINDNESS. SKIN:EXPOS TO LIQUID, VAP/MIST MAY CAUSE SEVERE SKIN
    IRRIT. (EFTS OF OVERXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ:SYMPS MAY INCL REDNESS, BURNING &
    SEVERE SKIN DMG. PRLNGD/RPTD EXPOS MAY CAUSE IRREVERSIBLE SKIN DMG
    INCL BURNS. INHAL:EXPOS IS POSS UNDER CERTAIN CNDTNS SUCH AS
    SPRAYING. PRLNGD/RPTD EXPOS M AY CAUSE IRREVERSIBLE RESP TRACT DMG.
    INGEST:EXPOS MAY BE HARMFUL/FATAL. SYMPS MAY INCL:SEVERE GI IRRIT
    (NAUS, (SUPDAT)
Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE EXISTING
    DERMATITIS OR OTHER SIGNIFICANT SKIN CONDITIONS. INHALATION MAY
    ADVERSELY AFFECT EXISTING RESPIRATORY CONDITIONS.

=======================  First Aid Measures  =======================

First Aid:EYES:IMMED REMOVE TO FRESH AIR. FLUSH W/WATER FOR @ LST 15
    MINS WHILE HOLDING EYELIDS APART. SEEK IMMED MED ATTN. SKIN:REMOVE
    CONTAMD CLTHG IMMED. WASH EXPOSED AREA W/LG AMTS OF SOAP & WATER.
    IF SKIN  IS DMGD/SYMPS DEVELOP, SEEK IMMED MED ATTN. INHAL:REMOVE
    TO FRESH AIR. IF BRTHG IS DFCLT, ADMIN OXYG (IF TRAINED IN ITS
    USE). IF BRTHG HAS STOPPED, GIVE ARTF RESP. KEEP PERSON WARM, QUIET
    & (SUPDAT)

=====================  Fire Fighting Measures  =====================

Flash Point Method:TCC
Flash Point:>212F,>100C
Extinguishing Media:WATER.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
    EQUIPMENT .
Unusual Fire/Explosion Hazard:PHOSPHORIC ACID IS CORR. HYDROGEN GAS MAY
    BE FORMED WHEN THIS PROD COMES IN CONT W/METALS. THIS PROD CONTAINS
    LG AMT OF WATER & WILL NOT BURN UNDER (SUPDAT)

==================  Accidental Release Measures  ==================

Spill Release Procedures:SM SPILL:ABSORB LIQ W/VERMICULITE, FLOOR
    ABSORB/OTHER ABSORB MATL. VENTILATE AREA WELL BEFORE RE-ENTRY.
    APPROP PERSONAL PROT EQUIP SHOULD BE WORN. LG SPILL:ONLY PERS
    TRAINED IN SPILL CLEAN-UP UNDER 29 CFR1910.120 SHOULD BE INVOLVED
    W/SPILL (ING 7)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:MINIMIZE TEMPERATURE EXTREMES. KEEP
    CONTAINERS CLOSED WHEN NOT IN USE. DO NOT TRANSFER TO UNMARKED
    CONTAINERS.
Other Precautions:LOOSEN CLOSURE CAREFULLY. CNTNRS USED TO TRANSPORT &
    STORE THIS MATL MAY BE HAZ WHEN EMPTIED. RESIDUE (VAPOR, LIQUID,
    AND/OR SOLID) MAY BE PRESENT IN EMPTIED CNTNR. ALL HAZARD
    PRECAUTIONARY MEASURES S HOULD BE FOLLOWED.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT REQD UNDER NORM CNDTNS OF USE; HOWEVER, IF
    SPRAYED/USED IN CONFINED AREAS, NIOSH APPRVD RESP MAY BE ADVISED IN
    ABSENCE OF PROPER ENVIR CTL. OSHA REGS ALSO PERMIT OTHER NIOSH
    RESPS UNDER SPECIFIED  CNDTNS--SEE 29CFR1910.134 OR (ING 11)
Ventilation:PROVIDE SUFFICIENT MECH VENT (GEN &/OR LOC EXHAUST) TO
    MAINTAIN EXPOSURE BELOW RECOMMENDED EXPOSURE LIMITS.
Protective Gloves:CHEMICAL RESIST GLOVES SUCH AS (ING 12)
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS (ING 13)
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER . TO
    PVNT RPTD/PRLNGD SKIN CONT, WEAR IMPERVIOUS CLTHG & BOOTS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
PH:ACIDIC (1.0). EXPLO HAZ:NORMAL FIRE CONDITIONS. MATLS TO AVOID:AND
    ALLOYS. DO NOT MIX WITH ANY PRODUCTS. EFTS OF OVEREXP:DIARR &
    VOMIT) AND BURNS TO MOUTH, THROAT, & DIGESTIVE TRACT. FIRST AID
    PROC :GET IMMED MED ATTN. IF POSS DO NOT LEAVE PERSON UNATTENDED.
    INGEST:DO NOT INDUCE VOMIT. VOMIT WILL CAUSE FURTHER(ING 5)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:17.5 @ 65F
Vapor Density:HVR/AIR
Spec Gravity:1.42
pH:SUPDAT
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:SOLUBLE
Appearance and Odor:PINK, CLEAR LIQUID.
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONT W/CYANIDES, SULFIDES, SULFITES, STRONG ALKALIES, & ORG
    MATLS. CORR CAN OCCUR IN CONT W/SOME METALS (SUPDAT)
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS INCLUDING,
    BUT NOT LIMITED TO FOLLOWING:ACID VAPORS, HYDROGEN GAS, & OXIDES OF
    PHOSPHOROUS.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF I/A/W ALL LOCAL, STATE, & FEDERAL
    REGS. THIS PROD MAY BE CLASSIFIED AS RCRA HAZARDOUS WASTE D002 DUE
    TO PH OF SOLUTION & CORROSIVE CHARACTERISTICS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.