GENERAL FIRE EXTINGUISHER CO -- FIRE EXTINGUISHER, HALON 1211 -- 4210-01-100-9086
=====================  Product Identification  =====================

Product ID:FIRE EXTINGUISHER, HALON 1211
MSDS Date:08/29/1995
FSC:4210
NIIN:01-100-9086
=== Responsible Party ===
Company Name:GENERAL FIRE EXTINGUISHER CO
Address:1685 SHERMER RD
City:NORTHBROOK
State:IL
ZIP:60062
Country:US
Info Phone Num:708-272-7500
Emergency Phone Num:708-272-7500,800-535-5053(INFOTRAC)
Preparer's Name:WILLIAM R. WARNOCK
CAGE:99539
=== Contractor Identification ===
Company Name:GENERAL FIRE EXTINGUISHER CORP
Address:1685 SHERMER RD
Box:City:NORTHBROOK
State:IL
ZIP:60062-5315
Country:US
Phone:(708)  847-272-7500; 847-272-7500
CAGE:99539

=============  Composition/Information on Ingredients  =============

Ingred Name:HALON 1211, BROMOCHLORODIFLUOROMETHANE (AS EXTINGUISHING
    AGENT)
CAS:353-59-3
RTECS #:PA5270000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: CONTACT WITH LIQUID MAY CAUSE
    FROSTBITE. USE OF EXTINGUISHER IN CLOSED AREA MAY CAUSE DANGEROUS
    CONCENTRATION OF HALON 1211. CHRONIC: NONE SPECIFIED BY
    MANUFACTURER.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:INHALATION: EXPOSURE TO CONCENTRATIONS OVER TWO
    PERCENT (8.5 LBS/1000 CUBIC FT.) MAY CAUSE DIZZINESS AND LACK OF
    COORDINATION.
Medical Cond Aggravated by Exposure:QUANTITY IN EXTINGUISHER UNLIKELY
    TO HAVE ANY EFFECT.

=======================  First Aid Measures  =======================

First Aid:REMOVE PERSON TO FRESH AIR AND VENTILATE CLOSED AREA.

=====================  Fire Fighting Measures  =====================

Flash Point:NON-FLAMMABLE
Extinguishing Media:ITEM IS A CHARGED FIRE EXTINGUISER, CHARGED WITH
    NON- FLAMMABLE HALON 1211. USE MEDIA APPROPRIATE FOR SURROUNDING
    FIRE.
Fire Fighting Procedures:NOT APPLICABLE. DLA-HMIS: WEAR SELF-CONTAINED
    BREATHING APPARATUS.
Unusual Fire/Explosion Hazard:NOT APPLICABLE.

==================  Accidental Release Measures  ==================

Spill Release Procedures:IF RELEASED, HALON 1211 WILL RAPIDLY EVAPORATE
    AND DIFFUSE INTO ATMOSPHERE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:HALON 1211 DEPLETES THE OZONE LAYER.
    DO NOT DISCHARGE THE EXTINGUISHER EXCEPT TO EXTINGUISH FIRE.
Other Precautions:DO NOT DIRECT STREAM OF DISCHARGED LIQUID AT OTHER
    PERSONS. PROTECT EXTINGUISHER FROM PHYSICAL DAMAGE. DO NOT EXPOSE
    TO TEMPERATURE ABOVE 125F.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:NOT NEEDED.
Ventilation:USE LOCAL EXHAUST AND/OR MECHANICAL (GENERAL) AS NEEDED IN
    CLOSED AREA AFTER FIRE IS EXTINGUISHED.
Protective Gloves:NOT NEEDED.
Eye Protection:NOT NEEDED.
Other Protective Equipment:NOT NEEDED.
Work Hygienic Practices:AVOID CONTACT WITH CONTENTS OF FIRE
    EXTINGUISHER.
Supplemental Safety and Health
NONE.

==================  Physical/Chemical Properties  ==================

HCC:G3
Boiling Pt:B.P. Text:25.0F,-3.9C
Vapor Pres:1897 @ 70F
Vapor Density:5.8
Spec Gravity:1.83
Evaporation Rate & Reference:NOT AVAILABLE
Solubility in Water:INSOLUBLE
Appearance and Odor:COLORLESS GAS AND LIQUID. SWEET ODOR.

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
WILL NOT EXTINGUISH FIRES IN ACTIVE METALS, METAL HYDRIDES, AND
    MATERIALS CONTAINING THEIR OWN OXYGEN.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:HALOGENS OR HALOGEN ACIDS MAY BE
    RELEASED IN FIRES. THESE ARE INDICATED BY BURNING IN EYES AND NOSE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:NOT APPLICABLE.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.